50A 22KW 30HP 415V Schneider Contactor D Range
Brand - Schneider
Model - LC1D50AN7
Range - TeSys
TeSys Deca
Range of Product - TeSys Deca
Product or Component Type - Contactor
Device short Name - LC1D
Contactor Application - Motor control
Resistive load
Utilisation category - AC-4
AC-1
AC-3
AC-3e
Poles Description - 3P
[Ue] Rated operational voltage - Power circuit: <= 690 V AC 25...400 Hz
Power circuit: <= 300 V DC
[Ie] Rated operational current - 50 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
50 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
[Uc] Control circuit voltage - 415 V AC 50/60 Hz
Complementary
Motor power kW - 15 kW at 220...230 V AC 50/60 Hz (AC-3)
22 kW at 380...400 V AC 50/60 Hz (AC-3)
30 kW at 500 V AC 50/60 Hz (AC-3)
33 kW at 660...690 V AC 50/60 Hz (AC-3)
25 kW at 415 V AC 50/60 Hz (AC-3)
30 kW at 440 V AC 50/60 Hz (AC-3)
11 kW at 400 V AC 50/60 Hz (AC-4)
15 kW at 220...230 V AC 50/60 Hz (AC-3e)
22 kW at 380...400 V AC 50/60 Hz (AC-3e)
30 kW at 500 V AC 50/60 Hz (AC-3e)
33 kW at 660...690 V AC 50/60 Hz (AC-3e)
25 kW at 415 V AC 50/60 Hz (AC-3e)
30 kW at 440 V AC 50/60 Hz (AC-3e)
Motor Power hp - 3 hp at 115 V AC 50/60 Hz for 1 phase motors
7.5 hp at 230/240 V AC 50/60 Hz for 1 phase motors
15 hp at 200/208 V AC 50/60 Hz for 3 phases motors
15 hp at 230/240 V AC 50/60 Hz for 3 phases motors
40 hp at 460/480 V AC 50/60 Hz for 3 phases motors
40 hp at 575/600 V AC 50/60 Hz for 3 phases motors
Compatibility code - LC1D
Pole contact composition - 3 NO
Protective cover - With
[Ith] conventional free air thermal current - 10 A (at 60 °C) for signalling circuit
80 A (at 60 °C) for power circuit
Irms rated making capacity - 140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
900 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity - 900 A at 440 V for power circuit conforming to IEC 60947
[Icw] Rated short-time withstand current - 400 A 40 °C - 10 s for power circuit
810 A 40 °C - 1 s for power circuit
84 A 40 °C - 10 min for power circuit
208 A 40 °C - 1 min for power circuit
100 A - 1 s for signalling circuit
120 A - 500 ms for signalling circuit
140 A - 100 ms for signalling circuit
Associated Fuse Rating - 10 A gG for signalling circuit conforming to IEC 60947-5-1
100 A gG at <= 690 V coordination type 1 for power circuit
100 A gG at <= 690 V coordination type 2 for power circuit
Average impedance - 1.5 mOhm - Ith 60 A 50 Hz for power circuit
Power dissipation per pole - 3.7 W AC-3
9.6 W AC-1
3.7 W AC-3e
[Ui] rated insulation voltage - Power circuit: 600 V CSA certified
Power circuit: 600 V UL certified
Signalling circuit: 690 V conforming to IEC 60947-1
Signalling circuit: 600 V CSA certified
Signalling circuit: 600 V UL certified
Power circuit: 690 V conforming to IEC 60947-4-1
Overvoltage category - III
Pollution degree - 3
[Uimp] rated impulse withstand voltage - 6 kV conforming to IEC 60947
Safety reliability level - B10d 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO
13849-1
Mechanical durability - 6 Mcycles
Electrical durability - 1.45 Mcycles 50 A AC-3 at Ue <= 440 V
1.1 Mcycles 80 A AC-1 at Ue <= 440 V
1.45 Mcycles 50 A AC-3e at Ue <= 440 V
Control circuit type - AC at 50/60 Hz standard
Coil technology - Without built-in suppressor module
Control circuit voltage limits - 0.3...0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz
0.8...1.1 Uc (-40…60 °C):operational AC 50 Hz
0.85...1.1 Uc (-40…60 °C):operational AC 60 Hz
1...1.1 Uc (60…70 °C):operational AC 50/60 Hz
Inrush Power in VA - 140 VA 60 Hz cos phi 0.75 (at 20 °C)
160 VA 50 Hz cos phi 0.75 (at 20 °C)
Hold-in power consumption in VA - 13 VA 60 Hz cos phi 0.3 (at 20 °C)
15 VA 50 Hz cos phi 0.3 (at 20 °C)
Heat dissipation - 4…5 W at 50/60 Hz
Operating time - 4...19 ms opening
12...26 ms closing
Maximum operating rate - 3600 cyc/h 60 °C
Maximum operating rate - 3600 cyc/h at 60 °C
IP degree of protection - IP20 front face conforming to IEC 60529
Protective treatment - TH conforming to IEC 60068-2-30
Climatic withstand - conforming to IACS E10 exposure to damp heat
conforming to IEC 60947-1 Annex Q category D exposure to damp heat
Permissible ambient air temperature around the device - 40…60 °C
60…70 °C with derating
Operating altitude - 0...3000 m
Fire resistance - 850 °C conforming to IEC 60695-2-1
Flame retardance - V1 conforming to UL 94
Mechanical robustness - Vibrations contactor open (2 Gn, 5...300 Hz)
Vibrations contactor closed (4 Gn, 5...300 Hz)
Shocks contactor open (15 Gn for 11 ms)
Shocks contactor closed (10 Gn for 11 ms)
Height - 122 mm
Width - 55 mm
Depth - 120 mm
Net weight - 0.855 kg
Packing Units
Unit Type of Package 1 - PCE
Number of Units in Package 1 - 1
Package 1 Height - 6.2 cm
Package 1 Width - 13.5 cm
Package 1 Length - 15.2 cm
Package 1 Weight - 926 g
Unit Type of Package 2 - S02
Number of Units in Package 2 -10
Package 2 Height - 15 cm
Package 2 Width - 30 cm
Package 2 Length - 40 cm
Package 2 Weight - 9.588 kg
18 Months Company Warranty
Advertisers are responsible for ensuring that advertising content, text, images, graphics ("Content") uploaded for inclusion on wedabima.com complies with all applicable laws. wedabima.com & D Factor Group assumes no responsibility for any illegality or any inaccuracy of the Content. wedabima.com and D Factor Group make no warranty or representation for any products, services, deals and transactions between the user and the advertisers. Users strictly at their own risk. The advertisers and user guarantees that his or her Content do not violate any copyright, intellectual property rights or other rights of any person or entity, and agrees to release wedabima.com and D Factor Group from all obligations, liabilities and claims arising in connection with the use of (or the inability to use) the service. Advertisers agree that their Content can may be presented through wedabima.com's partner sites under the same terms and conditions as on wedabima.com
wedabima.com and D Factor Group make no warranty or representation for any products, services, deals and transactions between the user and the advertisers. Users strictly at their own risk.
32A 15KW / 20HP 230V Schneider Contactor D Range price in Sri Lanka. Best deals from වැඩබිම.com for Hardware items in Sri Lanka. Brand - Schneider Model - LC1D32P7 Range of Product - TeSys Deca Product or Compon, etc... Find best deals from වැඩබිම
4 Pole 60A 230V Schneider Contactor D Range price in Sri Lanka. Best deals from වැඩබිම.com for Hardware items in Sri Lanka. Brand - Schneider Model - LC1DT60AP7 Range - TeSys TeSys Deca Range of Product - , etc... Find best deals from වැඩබිම
18A 7.5KW / 10HP 230V Schneider Contactor D Range price in Sri Lanka. Best deals from වැඩබිම.com for Hardware items in Sri Lanka. Brand - Schneider Model - LC1D18P7 Range of Product - TeSys Deca Product or Compo, etc... Find best deals from වැඩබිම
4 Pole 32A 230V Schneider Contactor D Range price in Sri Lanka. Best deals from වැඩබිම.com for Hardware items in Sri Lanka. Brand - Schneider Model - LC1DT32P7 Range - TeSys TeSys Deca Range of Product - T, etc... Find best deals from වැඩබිම
95A 45KW / 75HP 230V Schneider Contactor D Range price in Sri Lanka. Best deals from වැඩබිම.com for Hardware items in Sri Lanka. Brand - Schneider Model - LC1D95P7 Range - TeSys Range of Product - TeSys Dec, etc... Find best deals from වැඩබිම
40A 18.5KW / 25HP 230V Schneider Contactor D Range price in Sri Lanka. Best deals from වැඩබිම.com for Hardware items in Sri Lanka. Brand - Schneider Model - LC1D40AP7 Range - TeSys TeSys Deca Range of Prod, etc... Find best deals from වැඩබිම
All Risk Insurance Canada All Risk Insurance in Canada offers protection with comprehensive coverage against all forms of risk that may affect any asset owned by an individual or business.
First Time Business Loan in Canada Starting a business internationally often requires significant capital, and many first-time entrepreneurs seek International financing to kick-start their ven
Best United States Business Insurance Finding the best business insurance in the United States is crucial for protecting your company from financial losses and risks. The right insurance can sh
Startup Business Loans In USA Starting a business often requires significant funding, and for new entrepreneurs, securing the right financing is crucial. Startup business loans in the USA offer